Vue de la page 19
20 iRobot Verro Owner’s Manual
Checking the Flaps in the Vacuum Intakes
There is a flap just inside each vacuum intake at the bottom of the robot.
These flaps must freely open and close. If they do not, remove any dirt or
debris that is interfering with their operation.
Cleaning the Direction Baffle
Verro uses a baffle to redirect the flow of water so that it can move forward
and backward. If this baffle becomes fouled or clogged, Verro will not be able
to change direction.
To clean the direction baffle, direct a high-pressure jet of water from a hose
into the jet valve port. It may be helpful to remove the jet valve port (see
Cleaning the impeller, above) in order to see the direction baffle. Check to
make sure that it swings freely in both directions.